Salcor UV Disinfection Unit

Salcor UV Disinfection UnitThe Salcor Model 3G ultraviolet disinfection unit is specifically designed for disinfecting the effluent from aerobic treatment plants. It is able to reduce fecal coliform bacteria levels well below the most stringent US treatment standards.

A Salcor 3G unit is being tested in OSET Trial; 13, Rotorua 2017-18.

Salcor UV Disinfection UnitProtects Health and Environment

  • Outstanding Bacteria/Virus kill
  • Energy-efficient – less than 30 watts
  • No harmful By-products – Enables water reuse
  • Alarmed for reliable, continuous performance monitoring
  • 2 year warranty

 

Salcor UV Disinfection UnitResidential, Commercial, Municipal Uses

  • Gravity Flow to 4000,000 LPDF with Multiple units
  • Quick install in Ground/Pump tank – Minimal footprint
  • Reliable Continuous Performance Monitoring
  • 2yr Long Life lamp easily replaced
  • Teflon Barrier resists Fouling (Minimal Maintenance)

Third Party Tested and Approved

  • Only Floodproof UL certified unit (NEMA 6P)
  • University of Rhode Island 5yr Demo test
  • Outstanding NSF 6month tests with 19 different treatment systems

How it Works

Salcor UV Disinfection UnitThe 3G disinfection chamber is fixed directly to the aerobic plant (septic tank) discharge pipe and is permanently installed below ground. The ultraviolet light source for disinfection is mounted in a sub-assembly which can be inserted or removed through the top of the riser pipe for periodic servicing. The light source is mounted in the centre of an anodized aluminum frame which divides the disinfection chamber in half. The frame seals against the inner surface of the disinfection chamber to prevent flow bypass. When fully inserted, the disinfection sub-assembly is properly located by two pins mounted near the top of the disinfection chamber. The disinfection subassembly causes the wastewater entering one side of the unit to flow vertically downward, make a 180 degree turn, and then flow vertically upward and out the other side of the unit. This well-defined flow path is designed to give the fluid proper exposure time and no short circuiting. The ultraviolet light source is surrounded by a clear fused quartz tube to control the lamp surface temperature.

When the disinfection chamber is filled with water, the ultraviolet light source can operate continuously, whether or not water is flowing. Continuous operation with a lamp surface temperature range of between 40 and 49 degrees Celsius provides optimum ultraviolet light output and long lamp life.

The electrical subassembly is mounted in a junction box located on top of the 10cm riser pipe. The box contains fuses, alarm circuitry, UV lamp ballast, power cable connections, voltage surge protection, and electronic noise filters. The Salcor Model 3G alarm relay circuit triggers an external alarm to warn the user when the UV lamp is not operating properly. When the UV lamp is producing ultraviolet germicidal light at a safe level, a green LED indicator light, located on the top of the electrical junction box, glows indicating proper UV lamp operation. The light stops glowing when the light output from the UV lamp falls below a safe level or is not operating.